Technical data

Additional information
116
Coding 2
Call up coding level 2
The overview lists all possible coding addresses.
However, only those coding addresses are displayed which correspond to the
system type and equipment concerned and can be changed accordingly.
The coding addresses are structured in
accordance with the graphic on the
left.
Please note:
In the case of systems with one
system circuit and two mixing
valve circuits, the possible coding
addresses ”A0” to ”FF for
system circuit A1 are run through
first, then those for the mixing
valve circuits M2 and M3.
1. Press w and rw simultaneously
for approx. 2 seconds;
press
to confirm.
Access coding level 2.
2. Call up the required coding address
with the or button;
press to confirm.
3. Change the value with the or
button;
press to confirm.
Coding address flashes.
”Accepted” appears briefly in the
display, then the coding address
flashes again.
Further addresses can now be
selected with the
or button.
4. Press w and rw simultaneously
for approx. 1 second.
Exit coding level 2.
5285 941 v.1.5
System type
Cod. 00
Domestic hot water
Cod. 55 to 75
Boiler / Burner
Cod. 02 to 33
System circuit A1
Cod. A0 to FF
Mixing valve circuit M3
Cod. A0 to FF
Mixing valve circuit M2
Cod. A0 to FF
General
Cod. 7F to 95
Coding 2
Cod. 2
System type
Cod. 2