Operating instructions

117
Dis-
played
fault
code
Const. Weath.-
comp.
System char-
acteristics
Cause Measures
bC X Control mode
without remote
control
Communica-
tion error, re-
mote control
Vitotrol
heating circuit 1
(without mix-
er)
Check connec-
tions, cable, coding
address "A0" in
group "Heating
circuit" and re-
mote control set-
ting (see
page 156).
For wireless re-
mote controls:
Check connec-
tions, place remote
control unit close to
the boiler.
bd X Control mode
without remote
control
Communica-
tion error, re-
mote control
Vitotrol
heating circuit 2
(with mixer)
Check connec-
tions, cable, coding
address "A0" in
group "Heating
circuit" and re-
mote control set-
ting (see
page 156).
For wireless re-
mote controls:
Check connec-
tions, place remote
control unit close to
the boiler.
Troubleshooting
Fault codes
(cont.)
5772 909 GB
Service