Operating instructions

121
Dis-
played
fault
code
Const. Weath.-
comp.
System char-
acteristics
Cause Measures
dC X Control mode
without room
influence
Short circuit,
room temper-
ature sensor,
heating circuit 3
(with mixer)
Check room tem-
perature sensor,
heating circuit 3
dd X Control mode
without room
influence
Lead break,
room temper-
ature sensor,
heating circuit 1
(without mix-
er)
Check room tem-
perature sensor,
heating circuit 1
and remote control
settings (see
page 156)
dE X Control mode
without room
influence
Lead break,
room temper-
ature sensor,
heating circuit 2
(with mixer)
Check room tem-
perature sensor,
heating circuit 2
and remote control
settings (see
page 156)
dF X Control mode
without room
influence
Lead break,
room temper-
ature sensor,
heating circuit 3
(with mixer)
Check room tem-
perature sensor,
heating circuit 3
and remote control
settings (see
page 156)
E0 X Control mode Fault, exter-
nal LON sub-
scriber
Check connections
and LON subscrib-
ers
Troubleshooting
Fault codes
(cont.)
5772 909 GB
Service