Operating instructions
13
1. Pull the condensate hose far enough
out of the boiler that no unnecessary
bends are created inside the boiler.
Check the tightness of the siphon
connection.
2. ■ The condensate pipe is connected
with the discharge pipe of the
safety valve. The condensate hose
supplied meets the temperature
requirements that are part of the
CE certification.
■ We recommend the internal con-
nection of the condensate pipe to
the domestic drain, either directly
or via a tundish.
■ If the condensate pipe is routed
outside the building, use a pipe with
7
30 mm at least, and protect this
pipe from frost. Avoid long external
pipelines.
!
Please note
Frozen condensate pipes
can result in faults and dam-
age to the boiler.
Always insulate conden-
sate pipes against frost.
■ Observe local building regulations.
Connect condensate pipe
A
to the
public sewage system with a con-
stant fall and a pipe vent.
Observe the local waste water regu-
lations.
Note
Fill the siphon with water before com-
missioning.
Installation sequence
Condensate connection
5772 909 GB
Installation