Checking the burner gasket and burner gauze assembly
Check burner gasket A and burner
gauze assembly
E
for possible damage
and replace if required.
A
C
2x
2x
B
D
E
F
1.
Remove electrodes B.
2.
Undo two retaining clips C on ther-
mal insulation ring
D
and then
remove thermal insulation ring
D
.
3. Undo two Torx screws and remove
burner gauze assembly
E
with gas-
ket
F
.
Commissioning, inspection, maintenance