Operating instructions

97
Coding in the delivered condition Possible change
E2:50 With remote control: No
display correction for the
actual room temperature
(only for weather-com-
pensated control units)
E2:0
to
E2:49
Display correction –5 K
to
Display correction –0.1 K
E2:51
to
E2:99
Display correction +0.1 K
to
Display correction +4.9 K
E5:0 Without external variable
speed heating circuit
pump (only for weather-
compensated control
units)
E5:1 With external variable
speed heating circuit pump
(automatic recognition)
E6:... Maximum speed of the
variable speed heating
circuit pump in % of the
max. speed in standard
mode. Value is specified
by boiler-specific param-
eters (only for weather-
compensated control
units).
E6:0
to
E6:100
Maximum speed adjusta-
ble from 0 to 100 %
E7:30 Minimum speed of the
variable speed heating
circuit pump: 30 % of the
max. speed (only for
weather-compensated
control units)
E7:0
to
E7:100
Minimum speed adjustable
from 0 to 100 % of the max-
imum speed
E8:1 Minimum speed in opera-
tion with reduced room
temperature subject to
the setting in coding ad-
dress "E9" (only for
weather-compensated
control units)
E8:0 Speed subject to the set-
ting in coding address
"E7"
E9:45 Speed of the variable
speed heating circuit
pump: 45 % of the max.
speed during operation
with reduced room tem-
perature (only for weath-
er-compensated control
units)
E9:0
to
E9:100
Speed adjustable from 0 to
100 % of the maximum
speed during operation
with reduced room temper-
ature
Code 2
"Heating circuit ..."/group 5
(cont.)
5772 909 GB
Service