Operating instructions

107
Service menu:
1. Press OK + å simultaneously for
approx. 4 s.
2. "Coding level 1"
3. "Heating circuit 1"
or
"Heating circuit 2"
or
"Separate cooling circuit"
4. Select parameter.
Note
The parameters in the parameter groups
heating circuit 1, heating circuit 2 are
identical.
The assignment to the heating circuit is
determined by the first digit of the param-
eter code:
2xxx for heating circuit 1
3xxx for heating circuit 2
2000/2001/2022 Room temperatures and switching times
"Standard room temperature 2000"
"Reduced room temperature 2001"
"Party temperature 2022"
Adjusting the set room temperatures and
time programs for all heating circuits (A1,
M2).
Operating instructions
Delivered condition
200 ( 20 °C)
Setting range
100 to 300 ( 10 to 30 °C)
2003 Enabling the remote control
"Remote control 2003"
A Vitotrol 200 remote control unit can be
used for each heating circuit.
Vitotrol 200 installation instruc-
tions
Valu
e
Explanation
"1" Vitotrol 200 remote control for the
heating circuit is installed and
enabled.
"0" Remote control is not enabled.
Note
Remote control units have no function
when the heat pump is set to "Manual
mode".
Parameter group heating circuits/cooling circuit
Parameter group heating circuits
5441 603 GB
Service