Operating instructions

139
Parameter Code Delivered condi-
tion
Commis-
sioning
Internal hydraulics
Heat pump for drying a building 7300 0
Screed program 7303 0
Heating/DHW diverter valve 730D Do not adjust.
Set flow temperature, external demand 730C
500 ( 50 °C)
Primary source type 7320 0
Secondary pump type 7340 0
Heating water buffer cylinder
Buffer cylinder 7200 0
Fixed temperature 7202
500 ( 50 °C)
Hysteresis, buffer cylinder heating 7203
50 ( 5 K)
Maximum temperature 7204
600 ( 60 °C)
Temperature block fixed value mode buf-
fer cylinder
7208
100 ( 10 °C)
Heating circuit 1
Standard room temperature 2000
200 ( 20 °C)
Reduced room temperature 2001
200 ( 20 °C)
Party temperature 2022
200 ( 20 °C)
Remote control 2003 0
Heating curve slope 2006
12 ( 1.2)
Heating curve level 2007
0 ( 0 K)
Slope room hook-up 200A 10
Room temperature hook-up 200B 3
Maximum flow temperature 200E
400 ( 40 °C)
Heating circuit 2
Standard room temperature 3000
200 ( 20 °C)
Reduced room temperature 3001
200 ( 20 °C)
Party temperature 3022
200 ( 20 °C)
Remote control 3003 0
Heating curve slope 3006
12 ( 1.2)
Heating curve level 3007
0 ( 0 K)
Slope room hook-up 300A 10
Room temperature hook-up 300B 3
Maximum flow temperature 300E
400 ( 40 °C)
Commissioning/service reports
Control parameter report
(cont.)
5441 603 GB