Operating instructions
20
Assembly and sealing faces to note
A
1. Install the heat pump module in
reverse order to that described on
page 18.
With pipe outlets, ensure pipe glands
A
are seated correctly.
Seal pipe glands
A
with adhesive
tape.
2. Fit the cylinder module in reverse
order to that described on page 13.
!
Please note
Make tight hydraulic connec-
tions between the heat pump
and cylinder modules.
With pipe outlets, ensure pipe
glands
C
are seated cor-
rectly (see the following dia-
gram).
!
Please note
To prevent the formation of
condensate and extreme
noise development,
tightly seal the control unit
door.
Note
Because of the sound insulating mat,
the control unit door stands out
slightly when closed.
!
Please note
Seal the appliance to be
soundproof and diffusion-
proof.
Sealing tape on the side pan-
els must be in close contact
with sealing faces
B
on the
casing.
Installation sequence
Opening and separating the heat pump
(cont.)
5441 603 GB