Message overview
All messages are identified by a two-digit code.
Message
System characteristics Cause Measures
02 Std after data error
Delivered condition set
after recognition of data
fault
Reconfigure system.
03 Configuration fault
System configuration
fault:
■ Incorrect system
scheme (contains non-
supported heating cir-
cuit)
■ Max. flow temperature
for heating circuit <
min. flow temperature
for cooling the heating
circuit
■ Cooling for unavailable
heating circuit
Check and match associ-
ated parameters, reset to
delivered condition if
required ("Reset", see
operating instructions),
and reconfigure system.
Contact your local heating
contractor if the cause of
the fault cannot be rem-
edied.