Operating instructions
69
"Function check" menu
Function System characteristics
Heating circuit 1 Secondary pump and heating circuit pump A1 are
started.
Heating circuit 2 Heating circuit pump M2 starts. Open/close mixer
every 5 min.
Separate cooling circuit Primary pump and circulation pump, separate cooling
circuit are started. Open/close mixer every 5 min.
DHW (DHW cylinder) Secondary pump, circulation pump for cylinder heat-
ing (heating water side) and cylinder primary pump
(DHW side) are started.
Swimming pool Secondary pump is started. Swimming pool output is
switched on/off every minute.
Electric heater (instantane-
ous heating water heater,
accessory)
Secondary pump is started. Instantaneous heating
water heater regulates to a flow temperature of
30 °C.
Heat pump Primary pump and secondary pump are started. Heat
pump regulates to a return temperature of 30 °C.
Solar Solar circuit pump starts.
Note
If the Vitosolic is connected, only the display for the
solar circuit pump is activated in the system overview.
Start the solar circuit pump via the Vitosolic (see
Vitosolic service instructions).
Primary source
Note
The execution of this function
lasts 10 min.
The primary pump starts. The primary circuit flow
temperature is averaged every minute.
Note
This function determines the temperature of the
undisturbed ground.
If the function is terminated earlier, the average value
calculated at the time of the termination is saved.
Steps if the room temperature is too low
1. Vent the heating circuits.
Troubleshooting
Function check
(cont.)
5441 603 GB
Service