Operating instructions

80
Room cooling stops if the average out-
side temperature falls below 23 °C
(because of the specified hysteresis of
1 K).
Note
This parameter is only available if cool-
ing mode has been enabled via param-
eter "Cooling" (see page 110).
Delivered condition
40 ( 4 K)
Setting range
10 to 200 ( 1 to 20 K)
7010 External extension
"External extension 7010"
Enabling external extension H1.
External extension H1 can be used for
the following hook-ups/components:
Swimming pool water heating
External operating mode changeover
External demand
External mixer OPEN
External blocking
External mixer CLOSE
Note
Only one external extension can be con-
nected to the control unit.
If the components for swimming pool
heating are connected to "External
extension H1", no additional hook-up
(e.g. operating mode changeover) can
be connected to the "External extension
H1".
Valu
e
Explanation
"1" External extension H1 is installed
and enabled.
"0" External extension H1 is not ena-
bled.
Delivered condition 0
Setting 1 / 0
7008 Swimming pool
"Swimming pool 7008"
Parameter group system definition
7004 Temperature differential for the cooling…
(cont.)
5441 603 GB