Operating instructions

83
Value Operating mode (see operating instructions)
Heating DHW
"2" "Normal" "Normal"
"3" "Fixed value"
(see set flow temperature on
page 102)
"Temperature 2"
Delivered condition 2
Setting range 0 to 3
7013 Duration of external operating mode changeover
"Duration of operating mode changeover 7013"
Note
Only in conjunction with external exten-
sion H1.
Setting the minimum duration of exter-
nal operating mode changeover (see
also "Changing the heating circuit
operating mode 7011"). After expiry,
the control unit switches back to the
operating mode that was enabled before
the external operating mode change-
over. This also occurs if party mode was
enabled in the meantime.
Parameter group system definition
7012 Operating mode for external operating mode…
(cont.)
5441 603 GB