Operating instructions
86
Setting Heating circuit with mixer
M2
Heat pump blocking
0 Control mode No
1 Mixer "Close" No
2-3 Do not adjust.
4 Control mode Yes
5 Mixer "Close" Yes
6-7 Do not adjust.
Delivered condition 4
Setting range 0 to 8
7017 Vitocom 100
"Vitocom 100 7017"
Using the Vitocom 100 communication
interface.
Valu
e
Explanation
"1" Vitocom 100 is installed and ena-
bled.
"0" Vitocom 100 is not used.
Delivered condition 0
Setting 1 / 0
701B Common system temperature sensor
"Common system sensor 701B"
In systems with a heating water buffer
cylinder, a common flow temperature
sensor ("System flow temperature sen-
sor") can be installed in the heating water
flow, downstream of the heating water
buffer cylinder.
Valu
e
Explanation
"1" System flow temperature sensor
is installed and enabled.
"0" System flow temperature sensor
is not used. The flow temperature
sensor for the secondary circuit is
not used.
Parameter group system definition
7015 External blocking mixer "CLOSED"
(cont.)
5441 603 GB