Operating instructions

88
Service menu:
1. Press OK + å simultaneously for
approx. 4 s.
2. "Coding level 1"
3. "Compressor"
4. Select parameter.
5000 Enable compressor
"Enable 5000"
Enabling the compressor stage.
Note
Never block the heat pump compressor
in standard mode.
Valu
e
Explanation
"1" Compressor stage is used.
"0" Compressor stage is not used,
e.g. in case of a fault.
Delivered condition 1
Setting 1 / 0
5030 Heat pump output
"Output compressor stage 5030"
Type-dependent heating output of heat
pump.
This value is required to calculate the
energy statement and seasonal perform-
ance factor.
Delivered condition Specified via coding card according to rated heating output
of heat pump (e.g. 8 kW for type 108; see type plate for
rated heating output)
Setting range 1 to 255 kW
Parameter group compressor
Parameter group compressor