Operating instructions

89
Service menu:
1. Press OK + å simultaneously for
approx. 4 s.
2. "Coding level 1"
3. "DHW"
4. Select parameter.
6000 Set cylinder temperature
"Cylinder temperature DHW 6000"
DHW cylinder set temperature for DHW
heating.
Note
If the heat pump alone cannot achieve
the set DHW temperature, the instanta-
neous heating water heater (accessory)
is also started (if enabled via parameter
"DHW with e heating 6015").
Operating instructions
Delivered condition
500 ( 50 °C)
Setting range
100 to 700 ( 10 to 70 °C)
6015 DHW reheating
"DHW with e heating 6015"
DHW reheating enabled via instantane-
ous heating water heater (accessory).
If the set cylinder temperature cannot be
achieved with the heat pump, an instan-
taneous heating water heater (acces-
sory) can be used.
Note
The instantaneous heating water
heater (accessory) has to be enabled
separately with parameter "Inst. heat-
ing water heater 7900".
Observe setting for "Booster heater
hysteresis 6008".
Parameter group DHW
Parameter group DHW
5441 603 GB