VITOCELL 100-V Indirect-fired domestic hot water storage tank 42 to 119 USG / 160 to 450 ltr Technical Data Manual Model Nos.
Product Information VITOCELL 100-V The vertical tank solution for cost-efficient domestic hot water supply. The Vitocell 100-V DHW tank offers storage capacities of up to 119 USG / 450 ltrs. The benefits at a glance: H Corrosion-protected steel tank shell with Ceraprotect two-coat enamel finish. Magnesium anode provides additional cathodic tank protection. H Heat exchanger coil extends to the bottom of the tank, thereby heating the entire water content.
Product Information Cross-Section Magnesium anode Steel domestic hot water storage tank, with Ceraprotect two-coat enamel finish Recirculation tapping Boiler water supply 2¼”/58 mm PUR Foam or 4”/100 mm wrap-around PET insulation (HCFC-free) Boiler water return 5167 518 - 01 Non-finned tubular steel heat exchanger coil with Ceraprotect finish extends to tank bottom the entire water volume is heated, preventing cold spots where bacteria growth could occur Product may not be exactly as illustrated.
Technical Data Technical Data Storage Capacity Suitable H max. H max. H max. H max. for heating systems with working pressure on the heat exchanger side of up to 150 psig / 10 bar working pressure on DHW side of up to 150 psig / 10 bar supply temperature on the heat exchanger side of up to 230 °F / 110 °C DHW supply temperature of up to 150 °F / 65.6 °C USG ltr 42 160 53 200 79 300 119 450 MBH 194 °F GPM 90 °C ltr/h 136 4.3 982 136 4.3 982 180 5.7 1302 238 7.
Technical Data Dimensions Storage USG capacity ltr Vitocel 100l-V (42 and 53 USG / 160 and 200 ltr) IO a MA TPV DHW f Overall height b d AQ d e BWS c e f g c BWR Overall width RT h b Overall depth h jØ DCW/D inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm 42 160 53 200 79 300 119 450 –– –– 13 16½ –– –– 336 422 2¾ 2¾ 3 4 72 72 76 107 9¾ 9¾ 10 13¾ 249 249 260 349 25 25 34½ 36¼ 634 634 875 924 35 35 44 48½ 884 884 1115 1230 41 41 63 70¼ 1050
Technical Data Domestic hot water draw rate Storage tank contents heated to 140 °F / 60 °C, boiler not reheating Storage capacity USG ltr 42 160 53 200 79 300 119 450 DHW draw rate GPM ltr/min 2.6 10 2.6 10 4.0 15 4.
Multiple Tank Installation (79 and 119 USG / 300 and 450 ltr only) Technical Data The 79 and 119 USG / 300 and 450 ltr tank sizes may be combined into a battery consisting of between 2 and 4 tanks. Tank batteries consisting of more than 4 tanks can be installed by creating up to 4 batteries, each consisting of 4 tanks. The heating contractor is responsible to ensure proper piping on both the primary and secondary circuits.
Multiple Tank Installation (79 and 119 USG / 300 and 450 ltr only) For domestic hot water applications which utilize modulating and low temperature hot water heating boilers or remote heating plants Qty 2 Qty 3 Qty 4 IO DHW h TPV BWR h RT A BWR A A BWS BWS BWS e Depth Depth Depth Side view h h h a DHW/ D A b BWR Width c BWR IO Width h Width d BWS Top view Legend IO Inspection and clean-out opening D Drain A Air vent BWR Boiler water return BWS Boiler water supply DCW Do
Multilple Tank Installation (79 and 119 USG / 300 and 450 ltr only) Domestic hot water draw rate Storage tank content heated to 140 °F / 60 °C Storage capacity USG ltr 79 300 Battery storage capacity USG ltr 159 600 2 238 900 2 357 1350 3 476 1800 4 DHW draw rate GPM ltr/min 7.9 30 7.9 30 7.9 30 11.
Standard Equipment Product Installation Standard Equipment Vitocell 100-V 42 to 79 USG / 160 to 300 ltr capacity Vitocell 100-V 119 USG / 450 ltr capacity Domestic hot water storage tank of high-grade steel with PUR Foam insulation (HCFC-free) and Ceraprotect two-coat enamel finish with: Domestic hot water storage tank of high-grade steel with wrap-around soft PET insulation (HCFC-free) and Ceraprotect two-coat enamel finish with: H thermometer H adjustable leveling feet H built-in aquastat well H Magn
Product Installation Backflow preventers Warranty Sensor Well Where backflow preventers are required, a domestic water expansion tank installation is recommended in the cold water inlet piping before the cold water enters the Vitocell. For the backflow device, observe local plumbing codes and regulations. Our warranty for domestic hot water tanks states that the water heated must be of drinking (potable) water quality and that any water treatment equipment in use must function correctly.
Vitocell 100-V Sizing Continuous Flow Capacity Chart Vitocell 100-V, 42 and 53 USG / 160 and 200 ltr capacities Curve Domestic hot water 40 to 113°F / 4 to 45°C 5167 518 - 01 Curve Domestic hot water 40 to 140°F / 4 to 60°C 12 VITOCELL 100-V
Vitocell 100-V Sizing Continuous Flow Capacity Chart Vitocell 100-V, 79 USG / 300 ltr capacity Curve Domestic hot water 40 to 113°F / 4 to 45°C 5167 518 - 01 Curve Domestic hot water 40 to 140°F / 4 to 60°C VITOCELL 100-V 13
Vitocell 100-V Sizing Continuous Flow Capacity Chart Vitocell 100-V, 119 USG / 450 ltr capacity Curve Domestic hot water 40 to 113°F / 4 to 45°C 5167 518 - 01 Curve Domestic hot water 40 to 140°F / 4 to 60°C 14 VITOCELL 100-V
Vitocell 100-V Sizing Continuous Flow Capacity Chart Example: Vitocell 100-V, 119 USG / 450 ltr capacity 5167 518 - 01 Assume boiler output to tank is 170 MBH. Enter chart at left and draw horizontal line across to recovery rate of 203 GPH / 3.4 GPM for 140°F / 60°C domestic hot water under column B. Where the horizontal line intersects the 194°F / 90°C curve is the point of intersection for the diagonal line used to size the pump.
VITOCELL 100-V 5167 518 - 01 Technical information subject to change without notice. Printed on environmentally friendly (recycled and recyclable) paper.