Operating instructions

89
Brief scan Display
Open Therm extension (if installed)
F
9
Software
version
DHW heat-
ing status
External hook-up 0 - 10 V
Display in %
Checking outputs (relay test)
Weather-compensated control unit
1. Press OK and å simultaneously
for approx. 4 s.
2. "Actuator test"
The following relay outputs can be controlled subject to system design:
Display Explanation
Start base load Burner operates at minimum output; internal pump
starts
Start full load Burner operates at maximum output; internal pump
starts
Start internal output
Internal output (internal pump) enabled
Start valve heating Diverter valve set to heating mode
Start valve centre Diverter valve in central position (filling/draining)
Start valve cylinder Diverter valve set to DHW mode
Start htg circ pump HC2 Heating circuit pump output enabled (extension to heat-
ing circuit with mixer)
Open mixer HC2 "Mixer open" output enabled (extension to heating circuit
with mixer)
Close mixer HC2 "Mixer closed" output enabled (extension to heating cir-
cuit with mixer)
Start htg circ pump HC3 Heating circuit pump output enabled (extension to heat-
ing circuit with mixer)
Open mixer HC3 "Mixer open" output enabled (extension to heating circuit
with mixer)
Close mixer HC3 "Mixer closed" output enabled (extension to heating cir-
cuit with mixer)
Start outp. int. exten. H1 Output at internal extension enabled
Start AM1 output 1 Output A1 at extension AM1 enabled
Start AM1 output 2 Output A2 at extension AM1 enabled
Start EA1 output 1
Contacts P - S at plug aBJ for extension EA1 closed
Diagnosis and service scans
Diagnosis
(cont.)
5692 857 GB