Technical Manual

Vitosol 200-T, SPE Technical Data
3
5693 556 v1.0
Product Information
3
Specification
Vitosol 200-T 1.63 m
2
3.26 m
2
Number of tubes 9 18
Gross area ft
2
(m
2
) 28.63 (2.66) 57.26 (5.32)
Absorber area ft
2
(m
2
) 17.55 (1.63) 35.10 (3.26)
Aperture area ft
2
(m
2
) 18.84 (1.75) 37.57 (3.49)
Installation position (see figure below)
A, B, C, D, E, F
Spacing between collectors in. (mm) 1.73 (44) 1.73 (44)
Dimensions
Width
Height
Depth
in. (mm)
in. (mm)
in. (mm)
48 (1220)
89 (2260)
6.85 (174)
94 (2390)
89 (2260)
6.85 (174)
The following values apply to the absorber area:
(as tested by TUV testing laboratories in Europe)
– Optical efficiency
– Heat loss factor k1
– Heat loss factor k2
%
k1 W/(m
2
· K)
k1 W/(m
2
· K
2
)
73
1.21
0.0075
73
1.21
0.0075
Thermal capacity kJ/(m
2
· K) 8.4 8.4
Weight lb(kg) 126 (57) 249 (113)
Liquid content
(heat transfer medium)
USG (L) 0.124 (0.47) 0.243 (0.92)
Permissible operating pressure psig (bar) 87 (6) 87 (6)
Maximum stagnation temperature °F (°C) 518 (270) 518 (270)
Connection Ø in. (Ø mm) ¾ (22) ¾ (22)
Tested quality
The collectors meet the requirements of the “Blue Angel”
eco-label to RAL UZ 73.
Tested in accordance with Solar KEYMARK, EN 12975
and SRCC 0G-100
Vitosol 200-T 1.63 m
2
3.26 m
2
a in. (mm) 48 (1220) 94 (2390)
CR Collector return
CS Collector supply