Technical Manual

Vitosol 200-T, SPE Technical Data
5693 556 v1.0
4
Installation on Sloped Roofs
4
Design Information
Required roof area
Vitosol 200-T
1.63 m
2
3.26 m
2
Vertical installation Horizontal installation Vertical installation Horizontal installation
a in.
(mm)
98.4
(2500)
57.9 + 1.75*
(1470 + 44*)
98.4
(2500)
104 + 1.75*
(2640 + 44*)
b in.
(mm)
57.9 + 1.75*
(1470 + 44*)
98.4
(2500)
104 + 1.75*
(2640 + 44*)
98.4
(2500)
* space between collectors if multiple units are installed in an array.
Add dimension b for each additional collector.
Installation with roof brackets
This method of fixing can be applied universally on
all common roof covers.
The fixing system comprises roof brackets, mounting
rails, clamping brackets and screws.
Forces are applied to the roof structure in various ways,
including via the roof brackets and the roof cover. Roof
covers can be very different. Consequently, damage
cannot be completely excluded in the case of applied
loads.
Mounting bracket
Note: During installation, e.g. on sheet steel roofs,
the mounting rails are secured directly on to
the mounting brackets with T-bolts.
Use on-site fixing options to secure the brackets,
to the substructure.