Technical Manual

Vitosol 200-T, SPE Technical Data
9
5693 556 v1.0
9
Design Information
Installation Examples
Take venting into account when engineering the collector
array.
Note: Max. 215 ft
2
(20 m
2
) absorber collector area can
be connected in series to form a single array.
Vertical installation on sloped roofs, horizontal installation
or installation on supports
Single row installation; connection from the left or right
A Collector temperature sensor
Installation in several rows, connection from the left or right
A Collector temperature sensor
Horizontal installation on a sloped roof
1 collector array
With this type of connection, the “Evacuated tube
collector” function at the SCU control must be enabled.
2 or more collector arrays
With this type of connection, the “Evacuated tube
collector” function at the SCU control must be enabled.
A Collector temperature sensor
A Collector temperature sensor
[215 ft
2
([20
2
)