Technical data
Installation on Sloped Roofs
10
Installing the Mounting Frames (continued)
Installation dimensions for ten SV collector panels
6. Re-apply shingles, if required, and
ensure all roof penetrations are
thoroughly sealed with silicone
sealant.
7. Continue with mounting rail
installation on page 12.
Dimensions for Model SV collectors
Number
1 2 3 4 5 6 8 10
Dim. A mm
inches
1019
40
1019
40
1019
40
1019
40
1019
40
1019
40
1019
40
1019
40
Dim. B mm
inches
–– –– 1077
42½
1077
42½
1077
42½
1077
42½
1077
42½
1077
42½
Dim. C mm
inches
39.5
1½
68.5
2¾
79
3
79
3
89.5
3¼
89.5
3½
100
4
110
4½
Dim. D
*1
mm
inches
1019
40
A
2038
80¼
A+A
3115
122½
A+B+A
4192
165
A+2xB+A
5269
207½
A+3xB+A
6346
249¾
A+4xB+A
8500
334½
A+6xB+A
10654
419½
A+8xB+A
Dim. E mm
inches
1098
43¼
2175
85½
3273
128¾
4350
171¼
5448
214½
6525
256¾
8700
342½
10875
428
Dim. F mm
inches
87.5
3½
87.5
3½
98
4
98
4
108.5
4¼
108.5
4¼
119
4¾
129.5
5
*1
For static reasons, maintain the stated sequence. Maintain the dimensions A and B as far as possible. Roof brackets may also be offset
if you ne ed to locate roof joist. However, always maintain the overall dimension.
5285 710 v2.0
36¼” /
923 mm
16” /
154 mm
36¼” /
923 mm
36¼” /
923 mm
75” - 82½”