Technical data

Installation on Sloped Roofs
13
Installing the Solar Collectors
Rating plate
(must be on the outside of the
outer collectors)
Interconnecting pipes must be free from
damage and contamination. Lubricate all
plug-in joints (O-ring seals) on the
collectors. Us e only the s pecial grease
supplied with t he connection set.
On the first and last collector, the s ide
to which the rating plate is attached
must be on the outside. Ensure that
dimension “ r” is maintained for f irst and
last collector.
1. Hook the collector into its mounting
plates
and lay down onto the
mounting rails
.
2. Secure the collector with four
clamping brackets
onto the
mounting rails. Tighten the two
outer clamping bolts only. Turn the
grooved bolt
90°.
3. Insert the connecting pipe
until it
bottoms out inside the collector
connections.
Ensure interconnection pipe is centered
between collector.
Number of collectors
1 2 3 4 5 6 8 10
Dimension r
SV collector
inches
mm
0.8
21
0.8
21
1.2
31.5
1.2
31.5
1.7
42
1.7
42
2.1
52.5
2.5
63
Dimension r
SH collector
inches
mm
0.8
21
1.2
31.5
1.7
42
2.1
52.5
2.5
63
2.9
73.5
3.7
94.5
4.5
115.5
5285 710 v2.0
3.
3.
4x
8.
1.
5.
4.
2.
¾” /
21 mm
Do not stand on the collectors.
CAUTION
IMPORTANT
IMPORTANT
5285 710 v2.0
IMPORTANT
4. Position the second collector as in
step 1.
5. Carefully push the second collector
against the first and insert the
connecting pipes until they are
centered between the collectors.
Distance from the lower edge of the
installed collector should be
¾” / 21 mm.
6. Install all additional collectors.
Continued on following page.