Installing Freestanding Installation (on substructures)
Legend
Collector connection
Spacer lip of the connecting brace
Rating plate
7. Position the first collector into the
retaining plates and push right up to
the spacer lip of the connecting
brace.
Install the collector panel so that the
rating plate side of the first and last
collector is on the outside (note
sticker)! If only one collector is to be
installed, connect t he piping opposite
the nameplate side.
8. Insert the interconnecting pipes as
far as possible into the collector
connections.
Interconnecting pipes must be free from
damage and contamination. Lubricate all
plug-in joints (O-ring seals) on the
collectors. Us e only the s pecial grease
supplied with t he connection set.
9. Carefully push the next collector up
to the spacer lip and insert the
interconnecting pipes as far as
possible.
Ensure interconnection pipe is centered
between collectors.
10. Click clamping brackets
into the
collector edge at the top of all
supports.
11. Secure the connecting brace turned
by 180° to the next brace using
the clamping brackets between the
second and third, the fourth and
fifth supports, etc.
12. Tighten all screws.
5285 710 v2.0