Technical data
Installation on Flat Roofs
or Freestanding Installation
22
Installing Freestanding Installation (with weight inserts)
Collector connection
Spacer lip
Rating plate
9. Position the first collector into the
retaining plates and push right up to
the spacer lip of the connecting
brace.
Center the distance when fitting only
a single collector.
Install the collector panel so that the
ratingplatesideofthefirstandlast
collector is on the outside (note
sticker)! If only one collector is to be
installed, connect t he piping opposite
the nameplate side.
10. Insert the interconnecting pipes
as far as possible into the collector
connections.
Interconnecting pipes must be free from
damage and contamination. Lubricate all
plug-in joints (O-ring seals) on the
collectors. Us e only the s pecial grease
supplied with t he connection set.
11. Carefully push the next collector up
to the spacer lip and insert the
interconnecting pipes as far as
possible.
Ensure interconnection pipe is centered
between collectors.
12. Click clamping brackets
into the
collector edge at the top of all
supports.
13. Secure the connecting brace
turned by 180° to the next brace
using t he clamping brackets
between the s econd and third, the
fourth and fifth s upports, etc.
14. Tighten all screws.
5285 710 v2.0
9.
13.
10.
12.
11.
¶ 232 mm /
9.1”
IMPORTANT
IMPORTANT
IMPORTANT