Technical data

Installation on Flat Roofs
or Freestanding Installation
Installation on Flat Roofs
or Freestanding Installation
23
Installing Freestanding Installation (with weight inserts)
Model SV
Secure against slipping
*1
Secure against lifting
*2
Installation height above
ground level
ft.
m
<26
<8
26 - 66
8-20
66 - 328
20 - 100
<26
<8
26 - 66
8-20
66 - 328
20 - 100
Required weight at 25° lbs
*3
kg
694
315
1221
554
1748
793
317
144
670
304
1025
465
Required weight at 45° lbs
kg
1120
508
1856
842
2674
1213
282
128
493
224
762
346
*1
Securing against slipping requires no a dditional attachment to r oof.
*2
Securing against lifting requires additional attachment to roof or structure with wires or cables.
*3
Weights listed are the total of the ins ert weights and support slabs.
Model SH Secure against slipping
*1
Secure against lifting
*2
Installation height above
ground level
ft.
m
<26
<8
26 - 66
8-20
100<26
<8
66 - 328
20 -
26 - 66
8-20
66 - 328
20 - 100
Required weight at 25° lbs
*3
kg
712
323
1237
561
1764
800
342
155
695
315
1049
476
Required weight at 45° lbs
kg
1085
492
1863
845
2641
1198
291
132
560
254
827
375
*1
Securing against slipping requires no a dditional attachment to r oof.
*2
Securing against lifting requires additional attachment to roof or structure with wires or cables.
*3
Weights listed are the total of the ins ert weights and support slabs.
Supply and Return Piping Configuration
Vitosol 100
Models SV, SH
Installation of collectors, connection on
alternate sides, max. 12 collectors.
max. 12
B
A
C
Ø 28x1
Ø 28x1
Installation of collectors, single-sided
connection, max. 10 collectors.
max. 10
B
A
C
Ø 28x1
Ø 28x1
Supply (hot)
Return
Air v ent valve (shut-off ty pe)