Operating instructions
Rated output range in heating
mode
T
V/TR 50/30 °C
T
V/TR 80/60 °C
kW
kW
9 to 26
8.2 to
23.7
11 to 26
10.0 to
23.7
11 to 26
10.0 to
23.7
Rated thermal load range kW 8.4 to 27.1
10.3 to
31.3
10.3 to
36.5
Gas council no. 47-819-18 47-819-19 47-819-20
Connection values
*
1
relative to the max. load with
Natural gas H m
3
/
h
2.9 3.3 3.9
LPG P kg/h 2.1 2.4 2.9
Power consumption (max.) W 111 144 167
Gas fired condensing combi
boiler (DHW heating)
Permissible operat-
ing pressure
bar 10 10 10
Rated water volume
at ΔT = 35 K
l/
min
10.6 12.3 14.3
Set flow rate (max.)
l/
min
10.0 12.0 14.0
Weight without front panel (in-
stallation)
kg 34 39 39
Product ID
_-0085 BT 0029
Specification (cont.)
60
Specification
5354 802 GB
*1
The supply values are only for documentation purposes (e.g. in the gas contract applica-
tion) or to estimate the supplementary volumetric settings. Because of factory settings,
the gas pressure must not be altered from these settings. Reference: 15 °C, 1013 mbar.