Vitodens 100-W, WB1B Installation & Service
Installation Examples (continued)
Connections
System Layout 3
Vitodens 100-W, WB1B 26, 35 with...
- DHW storage tank
- one heating circuit
Primary pump L must pump into the boiler (as illustrated)
Note: The use of a low-loss header is recommended if the
water flow rate is less than 1.7 GPM (400 L/h) or
more than 6.2 GPM (1400 L/h).
The low-loss header is available as accessory part.
See page 49 in this manual for details on the low-
loss header.
Legend
AV Air vent
PRV Pressure relief valve
TPV Temperature and pressure relief valve
A Vitodens 100-W gas-fired condensing boiler
B External boiler/DHW controller (field supplied)
C Heating circuit
D Heating circuit pump (field supplied)
E DHW storage tank
F DHW tank temperature aquastat or sensor
G DHW circulating pump (field supplied)
H Closely spaced tees, 4x pipe Ø or 12” (305 mm)*
K Expansion tank
L Primary pump (boiler circuit, (field supplied)
*A low-loss header offers additional benefits not provided
by a pair of closely spaced tees. Viessmann strongly
recommends and prefers the use of a low-loss header
over closely spaced tees. Please see page 36 for details.
Maximum Flow Rates
4xpipe Ø
or 12” / 305 mm
PRV
TPV
AV
IMPORTANT
Model WB1B 26 35
t
Output Btu/h 83,000 108,000
30ºF (17ºC) rise (GPM) 5.5 ----
35ºF (19.5ºC) rise (GPM) 4.7 6.2
40ºF (22ºC) rise (GPM) 4.2 5.4