Installation guide

Side Wall Vent Installation (Coaxial)
15
Side Wall Venting Layouts (Coaxial) (continued)
Layout with basic coaxial vent kit and accessory componentry
Straight pipe
*2
3.3 ft./1 m long
or
1.6 ft./0.5 m long
Elbow, 87° (1 per carton)
Telescopic extension (sliding coupling)
Elbow, 45° (2 per carton)
Vent termination
(incl. wall flashings)
Important!
Total length of vent termination is
31”/787 mm. If required, the vent
termination may be shortened by max.
12”/305 mm (min. vent
termination length is 19”/483 mm)
(see page 18).
Protective screen
Warning!
Protective screen must be installed.
Mounting clip, white(useatleast2)
Brass adaptor (M8 x
5
/
16
- 18) and
Setofscrews(#8 x
3
/
8
”)
*2
Other lengths may be used provided that the
maximum equivalent vent length is not exceeded.
5368 815 v2.0 b
Fig. 6
1
2
3
4 5
6
7
8
9
Side wall venting layout, using basic vent components and
accessory parts for vent system 60/100, 80/125 and 100/150
For Vitodens WB2B boiler models 80/105 a transition adaptor
is required (see page 36).