Operating instructions
Value
address
34: ...
Internal
circulation
pump
Heating cir-
cuit pump
Heating cir-
cuit without
mixer
Heating cir-
cuit pump
Heating cir-
cuit with
mixer
Circulation pump for
cylinder heating
3 Control
funct.
Control
funct.
OFF OFF
4 Control
funct.
OFF Control funct. Control funct.
5 Control
funct.
OFF Control funct. OFF
6 Control
funct.
OFF OFF Control funct.
7 Control
funct.
OFF OFF OFF
8 OFF Control
funct.
Control funct. Control funct.
9 OFF Control
funct.
Control funct. OFF
10 OFF Control
funct.
OFF Control funct.
11 OFF Control
funct.
OFF OFF
12 OFF OFF Control funct. Control funct.
13 OFF OFF Control funct. OFF
14 OFF OFF OFF Control funct.
15 OFF OFF OFF OFF
16 ON Control
funct.
Control funct. Control funct.
17 ON Control
funct.
Control funct. OFF
18 ON Control
funct.
OFF Control funct.
19 ON Control
funct.
OFF OFF
20 ON OFF Control funct. Control funct.
21 ON OFF Control funct. OFF
22 ON OFF OFF Control funct.
23 ON OFF OFF OFF
Code 2 (cont.)
44
Coding