Operating instructions

Coding in the delivered condition Possible change
FA:20 Raising the set boiler
water temperature or
the set flow temperature
when changing from op-
eration with reduced
room temperature to op-
eration with standard
room temperature, by
20 %. See example on
page 103 (only for
weather-compensated
control units).
FA:0
to
FA:50
Temperature rise adjusta-
ble from 0 to 50 %
Fb:30 Duration for raising the
set boiler water tem-
perature or the set flow
temperature (see cod-
ing address "FA")
60 min. See example on
page 103 (only for
weather-compensated
control units).
Fb:0
to
Fb:150
Duration adjustable from
0 to 300 min;
1 step 2 min
Resetting codes to their delivered condition
Constant temperature control unit:
1. L + G simultaneously for
approx. 2 s.
2. e press.
Weather-compensated control unit:
1. L + G simultaneously for
approx. 2 s.
2. e "Factory set? Yes"
appears.
3. d to confirm
or
a/b to select "Factory set?
No".
Code 2 (cont.)
58
Coding
5692 672 GB