Operating instructions

Display screen Explanation
Htg. system valve Diverter valve set to heating mode
Valve in middle pos. Diverter valve in central position (filling/draining)
DHW valve Diverter valve set to DHW mode
Htg.cir.pump M2 On Mixer extension
Mix.valve open Mixer extension
Mix.valve closed Mixer extension
Intern.output On Output sK internal extension
Htg.cir.pump A1 On External extension H1
DHW pump On External extension H1
Recirc.pump On External extension H1
Centr.fault ind.On External extension H1
Constant temperature control unit
Press the following keys:
1. K + d simultaneously for
approx. 2 s.
2. a/b for the required relay out-
put.
3. d Relay test is completed.
The following relay outputs can be controlled subject to system design:
Display screen Explanation
1 Burner modulation base load
2 Burner modulation full load
3 Internal pump / output 20 "ON"
4 Diverter valve set to heating mode
5 Diverter valve in central position (filling/draining)
6 Diverter valve set to DHW mode
10 Output sK internal extension
11 Heating circuit pump A1 External extension H1
12 Cylinder primary pump External extension H1
14 Central fault message External extension H1
Checking outputs (relay test) (cont.)
64
Service scans