Operating instructions
Rated voltage 230 V~
Rated frequency 50 Hz~
Rated current 6 A~
Protection cl ass I
Protection IP X 4 D to
EN 60529
Permissible ambient temperature
&
during operation 0 to +40 °C
&
during storage
and transport -20 to +65 °C
Electronic temp era-
ture limiter setting: 82 °C
Temperatur e limiter
setting 100 °C (fixed)
Line fuse (mains) max. 16 A
Power consumption
&
Circulation pump max. 115 W
&
Burner max. 60 W
&
Control unit max. 10 VA
Gas fired boiler, category 13 kW: I
2ELL,category26kW:II2EL L3P
Rated output TV/TR 50/30 °C kW 4.2 to 13 6.6 to 26
Rated output range
for central heating kW 3.9 to 12.3 6.3 to 24.7
for DHW heating kW 3.9 to 16.7 —
Connect ion valu es
*
1
Relative to the max. load
with: with H
uB
Natural gas E 9.45 kWh/m
3
m
3
/h 1.77 2.6 5
34.02 MJ/m
3
l/min
Natural gas LL 8.13 kWh/m
3
m
3
/h 2.05 3.0 8
29.25 MJ/m
3
l/min
LPG 12.79 kWh/kg m
3
/h — 1.94
46.04 MJ/kg
Product ID _-0085
Product characteristics (to EnEV [Germany])
Rated output range kW 4.2to13 6.6to26
Efficiency µat
&
100 % of rated output % 96.0 96.3
&
30% of rated output % 107.4 107.4
Standby heat loss q
B,70
*
2
%0.8 0.7
Power consumption
*
2
at
&
100 % of rated output W 207 207
&
30 % of rated output W 69 69
Specification
118
Specification
5692 619 GB
*1
The supply values are only for reference (e.g. i n the gas contract application) or to esti-
mate the supplementary volumetric settings. Because of factory settings, the gas pres-
sure m ust not be altered from these values. Reference: 15°C, 1013 mbar.
*2
Max. limit to EnEV [Germany]