Operating instructions
Removing the burner and checking the burner gasket
(replace ga sket every two years)
A Nuts
B Differential pressure sensor
C Burner gasket
D Gas supply pipe
E Gas train
F Ionisation elec trode
G Earth stud
H Fan motor
K Ignition device
1. Switch OFF the control unit ON/
OFF switch and the p ower supply.
2. Clos e the gas shut-off v alve and
safeguard against reopening.
3. Pull off electrical cables from fan
motor H, differential pressure sen-
sor B,gasvalveE, ionisation
electrode F, ignition unit K an d
earth stud G.
4. Release gas supply pipe fitting D.
5. Rele ase four nuts A and remove
the burner.
!
Please note
Prevent dam age to the wir e
mesh.
Never rest the burner on the
gauze assembly.
Further details regarding the individual steps (cont.)
17
Initial start-up, inspection, maintenance
5692 619 GB