Operating instructions

Setting and test values Set value Initial start-up
Date:
By:
Static pressure mbar max. 57.5 mbar
Supply pressure (flow pr essure)
= for natural gas E mbar 17.4 to
57.5 mbar
= for natural gas LL mbar 17.4 to
57.5 mbar
= for LPG mbar 42.5 to
57.5 mbar
Tick gas type
Carbon dioxide content CO
2
&
at lower rated output %by
vol.
&
at upper rated output %by
vol.
Oxygen content O
2
&
at lower rated output %by
vol.
&
at upper rated output %by
vol.
Carbon monoxide content CO
&
at lower rated output ppm
&
at upper rated output ppm
Ionisation current µA min. 5 µA