Operating instructions
Removing the burner and checking the burner gasket
(replace gasket every two years)
1. Switch OFF the control unit ON/
OFF switch and the m ains electri-
cal supply.
2. Close the gas shut-off v alve and
safeguard against reopening.
3. Pull electrical cables off fan motor
A, differential pressure sensor
B,gasvalveC, ionisation elec-
trode D, ignition unit E and earth
F.
4. Release gas connection pipe G
fixing screws and fittings.
5. Releas e four nuts H and remove
the burner.
!
Important information
Prevent dam age to the wir e
mesh.
Never rest the burner on the
gauze assembly.
6. Check th e burner gasket K for
damage.
Generally, replace the burner gas-
ket every two years.
Further details regarding the individual steps (cont.)
19
Initial start-up, inspection, maintenance
5692 548 GB