Operating instructions

Checking the burner gauze assembly
Replace the bur ner gauze ass embly if
the wire mesh is damaged.
1. Remove electrodes A.
2. Remove thermal insulation ring B.
3. Releas e the six Torx sc rews C
and remove the burner gauze
assembly D.
4. Remov e the old gauze as sembly
gasket E.
5. Inser t a new burner gauze a ssem-
bly with a new ga sket, and secure
with six Torx screws.
Note
Torque: 3.5 Nm
6. Refit a ne w thermal insul ation
ring B.
Further details regarding the individual steps (cont.)
20
Initial start-up, inspection, maintenance