4. Check th e gas connections fo r
soundness.
Danger
Escaping gas leads to a risk
of explosion.
Check all fitting s for sound-
ness.
5. Connect the electrica l cables/leads
to each correspo nding component.
Checking the condensate drain and cleaning the siphon
1. Check at siphon A,thatthecon-
densate can freely drain.
2. Remov e the retaining cl ip and the
siphon.
3. Clean t he siphon.
4. Fit the siphon and secure with the
retaining clip.
Testing anode e arth current with an anode test device
Note
We recommend that the ma gnesium anode f unction is checke d annually. This
function check can b e made without interr upting operation, b y measuring the
earth current with an anode test device.