Operating instructions
Example 1: Mod ifying the stand ard
roomtemperaturefrom20°Cto26°C
A Boiler water or flow temperature in
°C
B Outside temperature in ° C
C Set room temperature in °C
D Heating circuit pump OFF
E Heating circuit pump ON
2. Adjust the set day temperature with
rotary selector ts.
The value will be automatically
adopted after approx. 2 seconds.
Accordingly, the heating curve is
adjusted along set room tempera-
ture axis C , which result s in modi-
fied start/shutdown characteristics
of the heating circuit p umps, if the
heating circuit pump logic is acti-
vated.
Reduced room temperature:
1. For two heating circuits – select
heating circuit:
&
Press a.
1r flashes on the di splay.
&
Select heating circuit A1 (heating
circuit wi thout mixer):
Press d.
&
Select heating circuit M2 (heating
circuit with mixer):
– Press a.
– 2r flashes on the display.
– Press d.
Further details regarding the individual steps (cont.)
36
Initial start-up, inspection, maintenance
5692 548 GB