Operating instructions
Example 2: M odifying the redu ced
room temperature fro m 5 °C to 14 °C
A Boiler water or flow temperature
in °C
B Outside temperature in ° C
C Set room temperature in °C
D Heating circuit pump OFF
E Heating circuit pump ON
2. Call up the set night temperature
with E.
3. Change this value with a and b.
4. Confirm the set value with d .
Instructing the system user
The system installer must hand the operating instructions to the system user
and instruct them in the operation of the system.
Scanning and resetting the maintenance display
The red fault indicator flashes when the limits set via coding address 21 and 23
have been reac hed. As regards the operating i nterface disp lay:
&
for constant tempe rature control units, the hours run (sub ject to setting) or the
given time interval and the clock symbol will flash
&
for weather-compensated control units "Maintenance" flashes.
Note
Set code 24:1 a nd then code 24:0, if maintenance is implemented before main-
tenance is displayed; the set maintenance parameters for hours run and interval
are then reset to 0.
Further details regarding the individual steps (cont.)
37
Initial start-up, inspection, maintenance
5692 548 GB