Operating instructions

Coding in
the as
delivered
condition
Address:
value
Function mode Coding
change
Address:
value
Possible change
must contain the follow-
ing heat-up details:
&
Heat-up data with
respective flow tem-
peratures
&
Max. flow temperat ure
achieved
&
Operating condi tion
and outside tempera-
ture during hand over
The function continues
after power failure o r
after the cont rol unit has
been switched OFF. The
heating pr ogram " rw"
will be started, after the
screed-dryi ng function
has been com pleted or if
the address is manually
set to 0.
F1:6
to
F1:15
Constant flow tempera-
ture 20 °C
F2:8
*
3
Time limit for party
operation 8 ho urs or
external operating
mode changeover via
push button
*
4
F2:0 No time limit for party
mode
F2:1
to
F2:12
Time limit adjustable from
1to12hours
*
4
*
4
F5:12
*
5
*
5
Run-on time of the
internal circulation
pump in heating mode
F5:0 No run-on time of the
internal circulation pump
F5:1
to
F5:20
Run-on time of the inter-
nal circula tion pump
adjustable from 1 to
Code 2 (cont.)
60
Coding
5692 548 GB
*3
Only for weather-compensated control unit.
*4
In hea ting program "rw", the party mode ends automatically when changing over to
operation with standard room temperature.
*5
Only for constant temperature control units.