VIVIX-S 1417N User Manual © Vieworks. 2017 All rights reserved. The specifications and related information in this manual may be changed without notice. Refer to Vieworks Download Syetem (VDS) for the latest version of manuals. Under copyright laws, this manual should not be reproduced, in whole or in part, without the written permission of Vieworks.
VIVIX-S 1417N User Manual Contents 1. Instruction ......................................................................................................................................... 7 1.1 Document Guide ..................................................................................................................................... 8 1.1.1 Caution .....................................................................................................................................................
VIVIX-S 1417N User Manual 2.1 Product Components............................................................................................................................ 21 2.1.1 Detector............................................................................................................................................................................21 2.1.2 SCU Lite (FXRP-02A)....................................................................................................................
VIVIX-S 1417N User Manual 2.9.3 Recommended Specifications of Grid ................................................................................................................43 3. System Configuration.................................................................................................................... 44 3.1 Detector Connection Methods ........................................................................................................... 45 3.1.1 Wireless Connection ............
VIVIX-S 1417N User Manual 4.3 Device Setting ........................................................................................................................................ 77 4.3.1 Software Installation ...................................................................................................................................................77 4.3.2 Setting Detector and SCU ................................................................................................................
VIVIX-S 1417N User Manual 7. Regulatory Information ................................................................................................................ 99 7.1 Medical Equipment Safety Standards ............................................................................................. 100 7.1.1 Medical Equipment Classification ..................................................................................................................... 100 7.1.2 Product Safety Standard ..........
VIVIX-S 1417N User Manual 1. Instruction This section gives basic information about this manual and safe product use. Document Guide Intended Use Product Use Safety Instruction Product Usage Guide Rev.1.
VIVIX-S 1417N User Manual 1.1 Document Guide This User Manual explains how to use the VIVIX-S 1417N detector made by Vieworks, X-ray interface unit, and other peripheral equipment. Use this manual to install, set up and manage the VIVIX-S 1417N detector as well as understand its various functions. 1.1.1 Caution If the user is not fully aquainted with this manual, the product can be malfunctioned or unsuspected problem can be happened due to carelessness.
VIVIX-S 1417N User Manual 1.2 Intended Use VIVIX-S 1417N detector is a digital X-ray imaging solution. It acquires images by detecting X-rays that has been passed through the human body. When X-ray photons pass through the scintillator in the detector, the photons convert to visible ray, and the visible ray is converted to electronic signals through TFTs – thin film transistors (a-Si).
VIVIX-S 1417N User Manual 1.3 Product Use This chapter provides instructions about the use of the product, disposal and the liability limit of Vieworks. 1.3.1 Product Usage 1 Only a physician or a legally certified operator should use this product. 2 The equipment should be kept in a safe and operable condition by maintenance personnel. 3 Follow the guidelines in this manual when installing and using this product. 4 Use only computers and image display monitors recommended in this manual.
VIVIX-S 1417N User Manual 1.3.3 Product Disposal Disposal of this product in an unlawful manner may have a negative impact on health and on the environment. When disposing of this product, therefore, be absolutely sure to follow the procedure that conforms to the laws and regulations applicable in your area. European Union (and EEA*) only This symbol indicates that this product is not to be disposed with your household waste, according to the WEEE Directive (2012/19/EC) and your national law.
VIVIX-S 1417N User Manual 1.4 Safety Instruction This product is designed and manufactured to ensure maximum safety of operation and to meet all the safety requirements applicable to electronic medical equipment. Follow these safeguards while using the products to prevent severe personal injury or substantial property damage. It is important to read and understand the contents of this manual before using the product. 1.4.
VIVIX-S 1417N User Manual To make it easy to disconnect the plug at any time, avoid putting any obstacles near the outlet. Otherwise, it may not be possible to disconnect the plug in an emergency. Do not place heavy objects, such as medical equipment on cables and cords. Do not pull, bend, bundle, or step on the cables and cords to protect their sheath from being damaged. Do not alter the cords. Doing so may damage the cords, which could result in a fire or electric shock.
VIVIX-S 1417N User Manual Because the equipment cable is long, take care that cables do not become tangled during use. Also, be careful not to get your feet caught in the cable. It may cause a malfunction of the equipment or injury to the user from tripping over the cable. Do not block the ventilation ports of SCU to prevent overheating. Overheating can cause product’s malfunctions and damages. 1.4.
VIVIX-S 1417N User Manual Be sure to charge the battery periodically (once a year) if it is not used for an extended period of time. The battery pack cannot be charged if it has been over discharged. Before discarding the battery pack, cover the terminals with adhesive tape or other insulators. Contact with other metal materials may cause fire or explosion. 1.4.5 Environment of Use Do not install the equipment in any of the locations listed below.
VIVIX-S 1417N User Manual 1.4.6 Temperature The product is not intended to supply heat to a patient. The temperature of contact area with a patient will not be exceeded 48℃ under the normal user environment. Do not use the equipment beyond the range of recommended operating temperature. Be sure to monitor the internal temperature related to the patient contact area to avoid any adverse effect to the patient. 1.4.
VIVIX-S 1417N User Manual 1.5 Product Usage Guide When using the equipment, take the following precautions. Otherwise, problems may occur and the equipment may not function correctly. 1.5.1 Calibration To ensure optimal system performance, it is important to verify that the system is calibrated correctly. Check if the calibration is performed after the equipment is completed to be installed or repaired. Do not try to use the system if the calibration has not been performed.
VIVIX-S 1417N User Manual 1.5.5 Use Limitations Vieworks software has the engineer mode operated by inputting the administrator password only. This mode should be operated by the person who is qualified by Vieworks. 1.5.6 Disposal Disposal of this product in an unlawful manner may have negative effects on human health and the environment. Be sure to follow the procedure which is in conformity with the laws and regulations applicable in your area. 1.5.
VIVIX-S 1417N User Manual 1.5.9 During Exposure This equipment is not protected (sealed) against liquids such as blood and medicine in the operating room. If necessary, wrap the equipment in a disposable cover when using it. Do not use the selected frequency channel (2.4 ㎓ and 5 ㎓ dual band) for other wireless devices. Mutual interference may affect the image data transmission rate. Do not use the detector near devices generating a strong magnetic field.
VIVIX-S 1417N User Manual 2. Product This section gives an instruction about the product components and their specifications. Product Components VIVIX-S 1417N Detector SCU Basic (FXRS-03A) SCU mini (FXRS-04A) SCU Lite (FXRP-02A) Batttery Pack Battery Charger Others Rev.1.
VIVIX-S 1417N User Manual 2.1 Product Components 2.1.1 Detector Product Name Model / Description VIVIX-S 1417N FXRD-1417NAW (3.0kg) Wireless Detector FXRD-1417NBW (3.0kg) A deco sheet attached on the detector can be different depending on each client company. 2.1.2 SCU Lite (FXRP-02A) Product Name Model / Description FXRP-02A (330g) SCU Lite DC Adaptor (BPM030S-24) Rev.1.
VIVIX-S 1417N User Manual 2.1.3 SCU (System Control Unit) Component Model / Description FXRS-03A (2.8kg) SCU Basic AC Power Cable (2m) 110V (1EA) / 220V (1EA) FXRS-04A (1.2kg) DC Power Supply SCU mini (BPM060S24F10 / 24V) AC Power Cable (2m) 110V (1EA) / 220V (1EA) You can choose one of the SCU models depending on the purpose of use. Rev.1.
VIVIX-S 1417N User Manual 2.1.4 Battery & Charger Component Image Model / Description FXRB-03A (115g, 4EA) Battery FXRC-02A (0.8kg) FXRC-03A (0.5kg, Option) Charger DC Power Supply (BPM060S24F10 / 24V) AC Power Cable (2m) 110V (1EA) / 220V (1EA) Rev.1.
VIVIX-S 1417N User Manual 2.1.5 Accessories Type Image Description Software (Viewer or SDK) Manuals Resource Tether Interface Cable (7m) Ether Con Cable (7m, Option) Cables Generator Interface Cable (15m) UTP LAN Cable (15m, Direct) CAT 5E , CAT6 or higher Velcro tape (25mm x 50mm / 6ea) Attached to the corners of bucky and the friction surface of a detector. Velcro tape (25mm x 100mm / 6ea) Used to change settings of detector NFC card through the NFC.
VIVIX-S 1417N User Manual The use of accessories and cables other than those approved and sold by Vieworks Co., Ltd. may result in increased release of electromagnetic waves or decreased stability of the equipment. Accessory equipment connected to the analog and digital interfaces must be certified according to the respective IEC standards. All combinations of equipment must be in compliance with IEC 60601-1-1 system requirements.
VIVIX-S 1417N User Manual 2.2 VIVIX-S 1417N Detector VIVIX-S 1417N is designed to acquire digital images by collecting x-ray signals and sereval conversion processes. You can use the acquired image (14” x 17” film size) diversely depending on the purpose of use. 2.2.
VIVIX-S 1417N User Manual 2.2.2 Drawing Sheet Item Description Dimensions (H × W × D) 384.0㎜ × 460.0㎜ × 15.0㎜ Curvature of Edges R15.0 The allowed tolerance of thickness of a detector is -2.0㎜ ~ +1.0㎜ under the ISO 4090 regulation. Rev.1.
VIVIX-S 1417N User Manual 2.2.3 Functions Side Name Description Tightens the tether interface cable. A Tether Interface Connector B Tether Interface Holder Used for fixing and releasing a tether interface cable C Function Buttons Checks the status of detector Activates specialized functions D AP ON /OFF Button AP ON/OFF Button : Turns on / off the AP mode E Power Button Detector power button Used for wired connection between a detector and SCU.
VIVIX-S 1417N User Manual Rear Name Description Indicates battery remains A LED Display Indicates status of wireless connection and information Indicates direction of the image Rev.1.5 B Handle A handle for carrying a detector C NFC Contacts Contacting part of the NFC tag D Lock Lever of the Battery Case Locks/Unlocks the case of the attached battery pack. E Speaker Sound output when contacting the NFC tag.
VIVIX-S 1417N User Manual 2.2.4 Deco Sheet Indication Info. Description A Image starting point Indicates the starting point of an original image. B Center of the detector Indicates the central position of detector. C Status indication logo D-G Certification logo Indicates the certification logos relating to a medical device. H Wireless communication logo Indicates that this model can be operated wirelessly. Indicates the operating state of detector.
VIVIX-S 1417N User Manual 2.2.5 Wireless Communication Item Specifications Wireless standard IEEE 802.11n/ac 2.412 ~ 2.472㎓ (13 Channels) Frequency range 5.18 ~ 5.24㎓ (4 Channels) 5.745 ~ 5.805G㎐ (4 Channels) Data transmission rate Modulation 802.11n: Max. 450Mbps (MIMO 3X3) 802.11ac: Max. 1300Mbps (MIMO 3X3) BPSK, QPSK, 16-QAM, 64-QAM, 256-QAM 2.4㎓: Max. 19dBm (per chain) Transmission power 5㎓: Max. 18dBm (per chain) Security WPA2-PSK Antenna Dual Band Antennas (3EA, In-built) 2.2.
VIVIX-S 1417N User Manual 2.3 SCU Basic (FXRS-03A) SCU Basic synchronizes the image and X-ray signal as locating among the detector, workstation and the Xray generator. You can use the SCU Basic directly when the power supplies to SCU Basic after connecting it under the VIVIX-S 1417N system environment 2.3.1 Specifications Item Specifications Model FXRS-03A Power supply Input: AC100 to 240V, 50/60㎐, Max. 2.0-0.8A Output: DC +24V 3.
VIVIX-S 1417N User Manual 2.3.3 Functions Front Side No. Name Description 1 Power switch Turns on/off the power of SCU Basic. (Including Green LED Lamp) 2 Fan Expels the air which flows into the SCU Basic. 3 Antenna Assists communications between the detector and SCU Basic. Indicates the operation and connection status of SCU Basic. 4 Rev.1.5 Status LED Blinking green: Booting Green: Completed to boot up Blue: The software is connected and ready to communicate.
VIVIX-S 1417N User Manual Rear Side No. Name 1 Description X-ray generator interface connector (D-SUB 15 pins x 2 EA, Female) EXT_INF1 EXT_INF1 : 1 ~ 15 EXT_INF2 EXT_INF2 : 16 ~ 30 Gigabit Ethernet port (1000BASE-T) 2 LAN port (Port 1, 2, 3) Port 1: Communicates between workstation and SCU Basic. Port 2, 3: Communicates between FXRD-1717S detector and SCU Basic when configuring multiple detectors.
VIVIX-S 1417N User Manual 2.4 SCU mini (FXRS-04A) SCU mini synchronizes the image and X-ray signal as locating among the detector, workstation and the Xray generator. You can use the SCU mini directly when the power supplies to SCU mini after connecting it under the VIVIX-S 1417N system environment 2.4.
VIVIX-S 1417N User Manual 2.4.3 Functions Front Side No. Name Description 1 Power switch Turns on/off the power of SCU mini. 2 Antenna Assists communications between the detector and SCU mini. Indicates status of SCU mini operation and connection. 3 Rev.1.5 Status LED Blinking green: Booting Green: Completed to boot up Blue: The detector is connected and ready to communicate.
VIVIX-S 1417N User Manual Rear Side No. Name Description 1 X-ray generator interface connector (D-SUB 15pin, Female) EXT_INF Gigabit Ethernet port (1000BASE-T) 2 LAN port (Port 1, 2, 3) Port 1: Communication between the workstation and SCU mini. Port 2, 3: Communication between FXRD-1717S detector and SCU mini when configuring multiple detectors. Indicats the status of PoE port.
VIVIX-S 1417N User Manual 2.5 SCU Lite (FXRP-02A) SCU Lite synchronizes the image and X-ray signal as locating between the detector and the workstation. You can use the SCU Lite directly when the power supplies to SCU Lite after connecting it under the VIVIX1417N system environment. 2.5.1 Specifications Item Specifications Model FXRP-02A Power supply Input: DC +24V 1.0A Max.
VIVIX-S 1417N User Manual 2.5.3 Functions Front Side No. Name Description Indicates the status of PoE port. 1 LINK LED Green : 1 Gbps Yellow : 100 Mbps PoE (Power over Ethernet) port (1000BASE-T) 2 POE Port Communication between the detector and SCU Lite. Supplies power to the detector. Rear Side No. Name Rev.1.5 1 LAN port 2 DC power input port 3 Power Switch Description Gigabit Ethernet port (1000BASE-T) Communication between the workstation and SCU Lite.
VIVIX-S 1417N User Manual 2.6 Battery Pack 2.6.1 Specifications Item Specifications Model FXRB-03A Type Lithium Ion Rated Power Supply Output: DC +7.6V Capacity 3,100㎃h Number of cell 2S1P (2 Series 1 Parallel) Operation Time 3 hours (when sleep mode is off) Cycle Life Approx. 500 times (Fully charged/Discharged completely, 1cycle) Dimension (H × W × D) 160.0 ㎜ × 61.8 ㎜ × 5.7 ㎜ Weight 115g 2.6.2 Drawing Sheet Rev.1.
VIVIX-S 1417N User Manual 2.7 Battery Charger (FXRC-02A) 2.7.1 Specifications Item Specifications Model FXRC-02A Simultaneous Charging 2 battery packs Charging time 2 1/2 hours Rated power supply DC +24V, 2A Max. Dimension (H × W × D) 192.0㎜ × 101.0㎜ × 26.0㎜ Weight 0.8 ㎏ 2.7.2 Drawing Sheet Rev.1.5 No. Name Description 1 Top / Bottom LED Indicates the location and status of a battery pack being charged.
VIVIX-S 1417N User Manual 2.8 Battery Charger (FXRC-03A) 2.8.1 Specifications Item Specifications Model FXRC-03A Simultaneous Charging 2 battery packs (FXRB-01A (1ea) / FXRB-03A (1ea)) FXRB-01A: 3 hours Charging time FXRB-03A: 2 1/2 hours Rated power supply DC +24V, 2A Max. Dimension (H × W × D) 163.6 ㎜ × 190 ㎜ × 34.0 ㎜ Weight 0.5 ㎏ 2.8.2 Drawing Sheet 1 3 2 No. Name Description Indicates the location and status of a battery pack being charged.
VIVIX-S 1417N User Manual 2.9 Others 2.9.1 X-ray Generator (Recommended Exposure Condition) Item Recommended condition X-ray energy range 40kVp ~ 150kVp Reliability (Lifetime Dose) 100Gy 2.9.
VIVIX-S 1417N User Manual 3. System Configuration This section gives information about the various connection / configuration ways among the detector, SCU, workstaton and X-ray generator. You can figure out the most suitable way of system configuration through this instruction. Detector Connection Methods Diagram System Configuration Generator Interface Configuring DR Trigger Interface Rev.1.
VIVIX-S 1417N User Manual 3.1 Detector Connection Methods You can organize wired or wireless connection between the VIVIX-S 1417N detector and SCU. You can also choose other connection ways suitable for the use environment in case of need. 3.1.1 Wireless Connection The images and data are transmitted between the VIVIX-S 1417N detector and SCU by wireless connection. A battry pack should be installed in the detector to use it under the wireless configuration.
VIVIX-S 1417N User Manual 3.1.2 Wired Connection Connect VIVIX-S 1417N detector and SCU with a tether interface cable to make a wired configuration. As the tether interface cable supplies power to the detector, a battery pack is not needed to be installed in the detector. We recommend you the wired connection method for the following cases. When continuous power supply to the detector is needed. When the detector is fixed in a bucky stand or on a table.
VIVIX-S 1417N User Manual 3.2 Diagram 3.2.
VIVIX-S 1417N User Manual 3.3 System Configuration This section gives information about the configuration modes of VIVIX-S 1417N detector, SCU, workstation and the generator. 3.3.1 AP Mode (SCU AP Mode) SCU AP mode is the wireless connection method that connecting the detector with SCU as the center wirelessly. If the device is connected on AP mode, Wi-fi function is turned on. Wireless function is turned off if the device is connected on Tether Interface Mode as it is a wired connection mode.
VIVIX-S 1417N User Manual 3.3.2 Tether Interface Mode Tether interface mode is the wired connection method that connecting the detector with SCU as the center. SCU & Detector SCU and the VIVIX-S 1417N detector are connected with the tether interface cable. Other connection ways of the tether interface mode are the same as the AP mode. Rev.1.
VIVIX-S 1417N User Manual 3.3.3 External AP Mode External AP mode is the wireless connection method that adding the external AP device instead of SCU. External AP & SCU The external AP and SCU are connected with a LAN cable. External AP & Detector The external AP and VIVIX-S 1417N detector are connected wirelessly. In this case, the external AP and the detector operate as AP (Access Point) and STATION respectively. Other connection ways of the tether interface mode are the same as the AP mode.
VIVIX-S 1417N User Manual 3.3.4 Detector AP Mode Detector AP mode is the wireless connection method that connecting the PC (Workstation) with the detector as the center wirelessly. Detector & PC (Workstation) The VIVIX-S 1417N detector and PC are connected wirelessly. In this case, the detector and the PC operate as AP (Access Point) and STATION respectively. Since SCU is not used for configuring the detector AP mode, you can only use the AED mode without a wired connection.
VIVIX-S 1417N User Manual 3.3.5 Detector Stand-Alone Mode You can use the Stand-Alone mode without making a wired or wireless connection. You should take images with the AED mode only when using the Stand-Alone mode. (Cannot use the DR Trigger mode.) The acquired images are stored in the internal storage of the detector in order and the images can be transmitted to the PC after connecting the detector to the PC. The transmitted images are removed automatically from the detector. Rev.1.
VIVIX-S 1417N User Manual 3.4 Generator Interface VIVIX-S 1417N detector provides AED and DR Trigger intertace as a generator interface way to acquire images by detecting X-ray. Mode AED Description The detector detects X-ray exposure from the generator automatically and then performs image acquisition without any cable connection. The detector and generator receive and send their signal to each other for image acquisition.
VIVIX-S 1417N User Manual 3.4.2 DR Trigger Interface Connect the detector and X-ray generator with a generator interface cable, and then acquire images by sending and receiving their signal. Signal Processing Steps 1 The detector receives EXP_REQ signal from the X-ray generator. 2 After the detector completes to prepare image acquisition, it sends the EXP_OK signal to the X-ray generator. 3 The X-ray generator confirms EXP_OK signal and generates X-rays.
VIVIX-S 1417N User Manual 3.5 Configuring DR Trigger Interface To configure the DR Trigger interface, SCU and the generator should be connected with a generator interface cable. Connect the one end of generator interface cable to EXT_INF port of SCU, and then connect the other end to the generator. Up to three generators can be connected with SCU Basic. Only a single generator can be connected with SCU mini. 3.5.
VIVIX-S 1417N User Manual 3.5.3 Line Trigger Each detector shares a signal signal by being connected with generators separately. Up to three X-ray generators can be connected to SCU. The connection of each detector and generator can be configured from VIVIX Setup. You should comprehend about a detector and X-ray generator to make correct exposure. Otherwise, X-ray can be exposed to the detector in different location.
VIVIX-S 1417N User Manual 3.5.4 EXT_INF Port Pin Map EXT_INF port is D-SUB 15 pin female connectors of SCU, and used for the generator interface. Product EXT_INF port SCU Basic (FXRS-03A) SCU mini (FXRS-04A) EXT_INF1 port pin map definition (1 ~ 15) Rev.1.5 No. Signal name I/O Type Color Ch.
VIVIX-S 1417N User Manual EXT_INF2 port pin map definition (16 ~ 30) No. Signal name I/O Type Color Ch.
VIVIX-S 1417N User Manual 3.5.5 Input / Output Circuit Exposure Request Input Circuit (EXP_REQ) Exposure Respond Output Circuit (EXP_OK) Rev.1.
VIVIX-S 1417N User Manual 4. Settings This section gives information about the way of installation, setting, and diagnosis to use a detector with SCU. Battery Pack Product Installation Device Setting Diagnosis of Devices Rev.1.
VIVIX-S 1417N User Manual 4.1 Battery Pack Detector and its attached devices should be installed by an authorized service engineer. If you encounter any problems, consult the sales representative or engineer in Vieworks. 4.1.1 How to Insert Battery Packs 1 Raise the two lock/unlock levers of a battery case. 2 Open the battery cover. 3 Insert a battery pack and close the battery cover. Rev.1.
VIVIX-S 1417N User Manual 4 Pull down the two lock/unlock levers of a battery case. Check if the battery is fully charged before using. Make sure that the battery pack is securely inserted. The remaining battery can be checked from the battery lamp on the side of detector or from the VIVIX Setup program. 4.1.2 How to take out a battery pack 1 Raise the two lock/unlock levers of a battery case. Rev.1.
VIVIX-S 1417N User Manual 2 Open the battery cover. 3 Take out a battery pack and close the battery cover. Rev.1.
VIVIX-S 1417N User Manual 4 Pull down the two lock/unlock levers of a battery case. Make sure to turn off the detector by pressing and hold the power button for 3 seconds before detaching a battery pack. All status LED lamps are off and then the detector is turned off. Rev.1.
VIVIX-S 1417N User Manual 4.1.3 How to charge a battery pack (FXRC-02A) The detector is battery-operated when it is connected wirelessly. Charge the battery pack fully before inserting it to the detector. Charging type 1 Before charging a battery pack, supply power to the charger with a power adapter. 1 Open the cover at the lower side of charger. 2 Put the FXRB-03A battery pack on the top of charger in the right direction. 3 Push the battery down until it is fixed in the charging part.
VIVIX-S 1417N User Manual Charging type 2 Before charging a battery pack, supply power to the charger with a power adapter. 1 Open the cover at the lower side of charger. 2 Insert the FXRB-03A battery pack into the slot until it clicks. Insert the battery pack in the direction of a ‘TOP’ printed part. 3 Close the cover at the lower side of charger. The charging time can be different depending on temperature and charging status of a battery.
VIVIX-S 1417N User Manual 4.1.4 How to charge a battery pack (FXRC-03A) Charging type 1 Before charging a battery pack, supply power to the charger with a power adapter. 1 Put the FXRB-03A battery pack to the bottom of a charger until it clicks. 2 The battery is started charging automatically. The charger light turns orange / green color when the battery is being charged / fully charged. 3 Disconnect the battery pack from the charger when the charging is completed. Rev.1.
VIVIX-S 1417N User Manual Charging type 2 Before charging a battery pack, supply power to the charger with a power adapter. 1 Put the FXRB-01A battery pack into the slot. 2 The battery is started charging automatically. The charger light turns orange / green color when the battery is being charged / fully charged. 3 Disconnect the battery pack from the charger when the charging is completed. The charging time can be different depending on temperature and charging status of a battery.
VIVIX-S 1417N User Manual This detector is designed to make a battery being discharged little by little during the detector is off. Therefore, remove the battery pack when the detector is not used for some time. Otherwise, over discharge may occur resulting in the shortened battery life. Do not use the charger around the paitent. Charge the battery with the charger provided by Vieworks. Securely plug the power cord of the charger into the AC outlet.
VIVIX-S 1417N User Manual 4.2 Product Installation This equipment should be installed by a service personnel authorized by Vieworks. This equipment must only be connected to the power with protective earth. 4.2.1 Connecting SCU Basic (FXRS-03A) 1 If you use the DR Trigger interface, connect the one end of generator interface cable to the EXT_INF port of SCU, and the other to the X-ray generator.
VIVIX-S 1417N User Manual If you use the wireless communication method, a tether interface cable is not needed as the image is transmitted wirelessly. 5 To supply power, connect the AC power cable to the AC power input port of SCU. 4.2.2 Connecting SCU mini (FXRS-04A) 1 If you use the DR Trigger interface, connect the one end of generator interface cable to the EXT_INF port of SCU mini, and the other to the X-ray generator.
VIVIX-S 1417N User Manual 4 To supply power, connect the DC power cable to the DC power input port of SCU mini. 4.2.3 Booting up SCU (Ex. FXRS-03A) 1 Turn on the power switch at the front side of SCU. 2 Check if the power switch of SCU lights up green. 3 Check if the status indicator is blinking in green after the power switch of SCU is permitted. 4 Check if the status indicator of SCU is blinking in green and turns to light up in the same color.