User Guide

52
Get function table:
Basic function
Get Function Length ID
Command
Type
Command Response Range
Comments
Code (ASCII) Code (Hex) (Three ASCII bytes)
Get-Contrast 8 g a 61 000 ~ 100 Gets Contrast value
Get-Brightness 8 g b 62 000 ~ 100 Gets Brightness value
Get-Sharpness 8 g c 63 000 ~ 100 Gets Sharpness value
Get-Color 8 g d 64 000 ~ 100 Gets Color value
Get-Tint 8 g e 65 000 ~ 100 Gets Tint value
Get-Volume 8 g f 66 000 ~ 100 Gets Volume value
Get-Mute 8 g g 67
000: OFF (unmuted)
001: ON (muted)
Gets Mute ON/OFF status
Get-Input select 8 g j 6A 000~ See Set-function table
Get-Power
status: ON/STBY
8 g l 6C
000: STBY
001: ON
Get-Remote
control
8 g n 6E
000 : Disable
001 : Enable
002 : Pass through
Get-Power Lock 8 g o 6F
000 : Unlock
001 : Lock
Get-Button Lock 8 g p 70
000 : Unlock
001 : Lock
Get-Menu Lock 8 g q 71
000 : Unlock
001 : Lock
Get-Tiling Mode 8 g v 76
000 : OFF
001 : ON
Get-Tiling
Compensation
8 g w 77
000 : OFF
001 : ON
Get-Tiling H by V
monitors
8 g x 78
01x~09x: H monitors
0x1~0x9 : V monitors
1. 2
nd
digital for H monitors
2.3
rd
digital for V monitors
Get-Tiling
Position
8 g y 79
000 : OFF
001~025
Get-ACK 8 g z 7A 000
This command is used to
test the communication
link.
Get-Thermal 8 g 0 30
000~100:
0~+100 deg C
-01~-99:
-1~-99 deg C
For specific models only
Get-Power on/
off log
8 g 1 31
000
(See below note)
For specific models only
Get-Date 8 g 2 32
000
(See the Set-Date
command)
For specific models only
Get- Time 8 g 3 33
000
(See the Set-Time
command)
For specific models only
Optional function
Get Function Length ID
Command
Type
Command Response Range
Comments
(ASCII) Code (ASCII) Code (Hex) (Three ASCII bytes)