User Guide

81
Get-Function table
A. Basic function
Get Function Length ID Command
Type
Command Response Range Comments
(ASCII) Code (ASCII) Code (Hex) (Three ASCII bytes)
Get-Bright-
ness
8 g b 62 000 ~ 100
Get-Volume 8 g f 66 000 ~ 100
Get-Mute 8 g g 67 000: Off
001: On (muted)
Get-Input
select
8 g j 6A 000~
100~
1. 1st digit for signal
detection: 0
means “no signal”;
1 means “signal
detected”
2. 2nd &3rd digit:
See Set-function
table
Get-Power
status: ON/
STBY
8 g l 6C 001: ON
000: STBY
Get-Remote
control
S g n 6E 000: Disable
001: Enable
002: Pass through
Get RCU mode
status
Get-Power
lock
8 g o 6F 000: Unlock
001: Lock
Get-Button
lock
8 g p 70 000: Unlock
001: Lock
Get-Menu
lock
8 g l 6C 000: Unlock
001: Lock
Get-ACK 8 g z 7A 000 This command is
used to test the com-
munication link
Get-Thermal 8 g 0 30 000~100:
0~+100 deg C
-01~-99:
-1~-99 deg C
Get-Opera-
tion time
*3.1.0
8 g 1 31 000 1. Accumulated
hours in 8-digit in-
teger (00,000,001~
99,999,999)
2. Could be reset
when FW update
and Factory initia-
tion
3. Reply in 4 strings
Get-Device
name
8 g 4 34 000 Reply in 6 strings
(max. 12 characters)
*3.1.0
Get-MAC ad-
dress
8 g 5 35 000 (for the model with
LAN)
Reply in 6
strings.*3.1.0