Service manual

User Presets
Number of User Presets (recognized timings) Available: 10 presets total in FIFO
configuration
Changing Modes
Maximum Mode Change Blank Time for image stability : 3 seconds (Max), excluding
Auto Adjust” time
Under DOS mode (640 x 350, 720 x 400 & 640 x 400), it should recall factory setting
when execute Auto Adjust
The monitor needs to do “Auto Adjust” the first time a new mode is detected
(see section “0-TouchFunction Actions”)
While running Change Mode, Auto Adjust or Memory Recall, the image shall blank
TFT LCD PANEL
Panel Source Identify
The panel code “S” for Samsung panel should be shown on following position,
(1) The lower right side of ID label. (see Figure 2)
(2) The lower right side of UPC label. (see Figure 3)
(3) The F/W version sticker or silkscreen on main board.
Viewsonic Corporation 10 VP2130b-1 Confidential - Do Not Copy