You can check the installation condition of the
camera unit when the troubleshooting in the EyeRIS
setup menu is displayed on
Troubleshooting screen
Switch to the
calibration menu
Enable/disable the
Auto Run function.
When this function
is checked, the
software starts
automatically
when the
computer is
started up.
Change the stylus pen
status.
If clicking / pressing
this by the mouse / the
stylus pen when PAUSE
CALIBRATION is indicated
on this button, the stylus
pen becomes unavailable.
If clicking this by the
mouse when RESUME
CALIBRATION is indicated
on this button, the stylus
pen becomes ready to
use.
Check the camera recognition area
Press four corners of the projection screen by the stylus pen.
A red square is indicated on the troubleshooting screen and it can be checked all
area of the screen surface is in the camera recognition area.
Check inuence of external light
If the camera and/or the screen is exposed to strong light, it may cause of
malfunction because the computer cannot recognize the stylus pen. If a red
square is indicated on the screen without touching the screen by the stylus pen,
it means the camera and/or the screen get inuence of external light. In this
case, change the place to install them avoiding to receive direct sunshine or
strong light.
When the Touch Module is mounted beside a window, avoid receiving inuence
of light from outside by appropriate measures as closing a curtain and keeping a
certain distance from the window, etc.