Lamp Swapping Instruction

1
Replacing the lamp
Turn the power o󰀨 and disconnect the projector from the power outlet.
y To reduce the risk of electrical shock, always turn the projector o󰀨 and disconnect the power cord
before changing the lamp.
y To reduce the risk of severe burns, allow the projector to cool for at least 45 minutes before replac-
ing the lamp.
y To reduce the risk of injuries to ngers and damage to internal components, use caution when re-
moving lamp glass that has shattered into sharp pieces. Before replacing the lamp, clean the lamp
compartment and dispose of cleaning materials. Be careful of sharpedges in the lamp compart-
ment. Wash hands after lamp replacement.
y Only ViewSonic certied lamps are tested with this projector. Use of other lamps may cause electri-
cal shock and re.
y Wear working gloves during lamp replacement.
y Unplug projector power at least 10 minutes before replacing the lamp.
1. Turn the power o󰀨 and disconnect the projector from the wall socket. If the lamp is hot, avoid burns
by waiting for approximately 45 minutes until the lamp has cooled.
2. Loosen the screw that secures the lamp cover of the projector
until the lamp cover loosens. Then push the lamp cover forward
and lift it up.
3. Remove the lamp cover from the projector.
CAUTION
y Do not turn the power on with the lamp cover removed.
y Do not insert your ngers between the lamp and the projector.
The sharp edges inside the projector may cause injuries.
4. Disconnect the lamp connector.
5. Loosen the screw that secures the inner lamp.
6. Lift the handle so that it stands up.
2-1
2-2
4
6
5