Service manual

ViewSonic Corporation Confidential - Do Not Copy VA902-3_VA902b-3
18
5. Adjustment Procedure
1. Function Test
1.1. Product
- 19” LCD Monitor
1.2. Test Equipment
- Color Video Signal & Pattern (or PC with SXGA resolution and a sound card)
1.3. Test Condition
Before function test and alignment, each LCD Monitor should be run-in and warmed up for
at least 30 minutes with the following conditions:
(a) In room temperature,
(b) With full-white screen, RGB, and Black
(c) With cycled display modes,
640*480 (H=43.27kHz, V=85Hz)
800*600 (H=53.7kHz, V=85Hz)
1024*768 (H=68.67kHz, V=85Hz)
1280*1024 (H=79.97kHz, V=75Hz)
1.4. Test Display Modes & Pattern
1.4.1 Compatible Modes
Item Timing
1 640 x 350 @ 70Hz, 31.5kHz
2 640 x 400 @ 60Hz, 31.5kHz
3 640 x 400 @ 70Hz, 31.5kHz
4 640 x 480 @ 50Hz, 24.7kHz
5 640 x 480 @ 60Hz, 31.5kHz
6 640 x 480 @ 67Hz, 35.0kHz
7 640 x 480 @ 72Hz, 37.9kHz
8 640 x 480 @ 75Hz, 37.5kHz
9 640 x 480 @ 85Hz, 43.27kHz
10 720 x 400 @ 70Hz, 31.5kHz
11 800 x 600 @ 56Hz, 35.1kHz
12 800 x 600 @ 60Hz, 37.9kHz
13 800 x 600 @ 75Hz, 46.9kHz
14 800 x 600 @ 72Hz, 48.1kHz
15 800 x 600 @ 85Hz, 53.7kHz
16 832 x 624 @ 75Hz, 49.7kHz
17 1024 x 768 @ 60Hz, 48.4kHz
18 1024 x 768 @ 70Hz, 56.5kHz
19 1024 x 768 @ 72Hz, 58.1kHz
20 1024 x 768 @ 75Hz, 60.0kHz
21 1024 x 768 @ 85Hz, 68.67kHz
22 1152 x 864 @ 75Hz, 67.5kHz
23 1152 x 870 @ 75Hz, 68.7kHz
24 1280 x 1024 @ 60Hz, 63.4kHz
25 1280 x 1024 @ 75Hz, 79.97kHz
26 1280x 720 @ 60Hz, 45kHz (HDTV)