6.5.4 Adding TRX
You can add the same number of TRX that you have
specified during the addition of BTS. If you have not
specified any TRX for a BTS then you cannot add any TRX
for the BTS. In addition, you cannot modify the Number of
Trx field of BTS after the addition of BTS. Therefore, you
can only add the number of TRX as specified in BTS
configuration.
Follow these steps to add a TRX:
1. Open the BSS node in the modify mode.
2. Expand BTS-IF, right-click BTS :<IP address>, and
select Add Element.
3. In the Add TRX dialog box, select TRX as ME type and
click Ok.
The Configuration – Add Row dialog box appears.
LNote: You may receive an error that no more rows can be
added because the maximum number of TRX that can be
added in BTS should not exceed the value specified in the
Number of TRX field in BTS configuration window.
The configurable fields for TRX configuration are described
in the following table:
Table 26: TRX Fields
Field Name Description Values
BTS ID Indicates the BTS ID. 0 to 4294967294
Ptrx ID Indicates the physical TRX ID. 1 to 40
Admin State Indicates the administrative status of locked/unlocked