BSS C ONFIGURATION AND U SER G UIDE
Page 122 Commercial in Confidence © VNL
®
2010-2011, All rights reserved
7.3.3.2 Adding NSVC
Network service virtual connection (NSVC) exists between
the BSS and the SGSN. The network service (NS) layer is
responsible for managing these NSVCs and transfer of
upper layer packets.
You can add NSVC by following the below steps:
1. Open the BSS node in the modify mode.
2. Expand StackConfig, right-click GB Interface, and click
Add NSVC.
The Configuration – Add Row dialog box appears.
The various fields are explained in the following table:
Table 31: NSVC Fields
Field Name Description Values
NSVC ID Indicates the NSVC
identifier that uniquely
identifies NSVC within
BSS and SGSN.
0 to 65535
Admin State Indicates the
administrative state of
the NSVC. This is a
read-only field.
locked/unlocked
FR Channel ID Indicates the unique
FR channel identifier.
1 to 26
dlci Indicates the data link
connection identifier
of the PVC of FR link.
16 to 991